For more information on the CRYO XC™ Plus, CRYO XC™ & CRYO LC visit our product pages

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Systems

Pressurized | Non-Pressurized

Pressurized system

Non-Pressurized system

PRESSURIZED

Non-PRESSURIZED

Description

The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
 

The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

AVAILABILITY

CRYO XC™ Plus
CRYO XC™

CRYO XC™ Plus
CRYO XC™

MEDIUM

The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

Storage

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

CONSUMPTION

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

ROOM REQUIREMENTS

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

SUITABLE FOR

High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

APPROVAL

The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

WELCOME TO THE CONFIGURATOR

What is the purpose of the Configurator?

  1. Learn more about our products, ranging from systems, color options and orientation to dimensions, packaging, warranties and the order process.
  2. Personalize the CRYO XC™ to fit your needs and your brand.
  3. Save time by getting a more precise quotation for our equipment and services.

Terms of Use

  1. All information provided in the Configurator is for informational purposes only.
  2. Submitting a form through the Configurator does not give the user any obligation to purchase selected products or services.
  3. The Configurator is intended to guide the user through the options and provide the user with more detailed information.
  4. All product customization and service options are subject to availability.

GO TO NEXT STEP

CRYO XC™ Plus & CRYO XC™

Model features

Cryo XCTM PlusCryo XCTM
MODELS Cryo XCTM Cryo XCTM Plus
Description
The CRYO XC™ is CRYONiQ's best-seller. Designed to offer a balanced cryotherapy session and maximum exposure to extreme temperatures.
The CRYO XC™ Plus is CRYONiQ's flagship cryotherapy chamber which offers an enhanced cryotherapy experience for clients and operators with additional safety and design features.
Features
21,5" Touchscreen - Control Panel
15" Multimedia/Info Screen
Thermal Contrast Cryotherapy 
Adaptable Orientation
Lift
Deflectors
Active Drying System
Session Tracker
Remote Diagnostics
Safety Relief Vent
Exhaust Fan
Oxygen Monitoring
Door Sensor
Humidity Tracking
Pressure Tracking
Tremor Emergency Stop
Heart Rate Monitor

Systems

Pressurized System
Available
Compare
Available
Compare
Non-Pressurized System
Available
Compare
Available
Compare

SESSION TEMPERATURE (Exclusions Apply)

Temperature Range (Recommended)
170°F to -200°F
-110°C to -140°C
-170°F to -200°F
-110°C to -140°C
Temperature Range (Expanded)
-170°F to -240°F
-110°C to -160°C
-170°F to -240°F
-110°C to -160°C

STORAGE TANKS

Pressurized System
Tanks not included
Tanks not included
Non-Pressurized System
2x 50 liter vessel included
2x 50 liter vessel included

LN2 CONSUMPTION 

Pressurized System
5 - 8 liters (LN2)
5 - 8 liters (LN2)
Non-Pressurized System
4 - 7 liters (LN2)
4 - 7 liters (LN2)
Precool
2 - 4 Liters (LN2)
2 - 4 Liters (LN2)

ELECTRICAL SPECIFICATION

Outlet Voltage
230V
230V
Frequency
50 Hz
50 Hz
Amperes (Amps)
min. 16 A
min. 16 A
Power Usage
Max: 4000W
Idle: 140W
Session: 1000W
Drying: 3400W
Max: 4000W
Idle: 140W
Session: 1000W
Drying: 3400W

Certification

CE Mark
FDA 513g Non-Medical Device

LEAD TIME

New & Made-To-Order
4 to 6 weeks from valid order
4 to 6 weeks from valid order
Existing Inventory | Stock Items
1 to 2 weeks from valid order
1 to 2 weeks from valid order
Pre-Owned Inventory
1 to 2 weeks from valid order
1 to 2 weeks from valid order
Express Delivery
Faster Delivery of Made-To-Order Equipment
Faster Delivery of Made-To-Order Equipment

Warranty

2 Year Limited Service Warranty
2 Year Limited Parts Warranty
3 Year Limited Service Warranty
Available
Available
3 Year Limited Parts Warranty
Available
Extended Warranty
Available
Available

SERVICES (Exclusions Apply)

Door to door delivery
On-Site Install
On-Site Operator Training
24/7 Tech Support
First LN2 Fill for Operator Training*
Risk Assessment (Remote)

PROJECT ASSISTANCE (Exclusions Apply)

LN2 Supplier Sourcing
Available
Available
Financing Options | Lease Options
Available
Available
Insurance Options
Available
Available
Safety Regulations | Risk Assessment
Available
Available
Operation Guidelines
Available
Available



Cryo XCTM

CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in white

Advanced

Safety Features

2 Available

2 Available

Systems

Thermal Contrast

Cryotherapy

4 Integrated

Safety Features

10+ Unique

10+

Features

Thermal Contrast

Cryotherapy

10 Integrated

Safety Features

15+ Unique

15+

Features

Thermal Contrast

Cryotherapy

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Systems

Pressurized | Non-Pressurized

Pressurized system

Non-Pressurized system

PRESSURIZED

Non-PRESSURIZED

Description

The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
 

The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

AVAILABILITY

CRYO XC™ Plus
CRYO XC™

CRYO XC™ Plus
CRYO XC™

MEDIUM

The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

Storage

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

CONSUMPTION

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

ROOM REQUIREMENTS

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

SUITABLE FOR

High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

APPROVAL

The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

Lorem ipsum content

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec consectetur nisl ligula, ut suscipit massa dictum eu. Proin vulputate orci et fringilla sollicitudin. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Aenean porta dolor vel lacus molestie porttitor. Fusce lectus velit, tincidunt vel sapien in, mollis tempor ligula. Nam vitae mattis elit, ut commodo felis. Integer fermentum porta urna, vel faucibus turpis pellentesque nec. Interdum et malesuada fames ac ante ipsum primis in faucibus. Suspendisse potenti. Quisque ornare tincidunt purus. Integer eu nulla vel ipsum malesuada placerat. Quisque placerat finibus elit eu vestibulum.

Capacity & Readiness

CRYO XC™  |  Pressurized System

The CRYO XC™ Pressurized System is suitable for:

  • High Capacity & Footfall locations.
  • Wellness / Recovery centers, Sports clubs, Fitness centers, Training centers & Rehabilitation facilities.

The CRYO XC™ Pressurized System cryotherapy chamber runs on electric power while using liquid nitrogen to cool the cabin.
For this system, Liquid Nitrogen is stored in pressurized/nitrogen tanks with various capacities available from 70 liters up to thousands of liters.
Standard capacities of nitrogen tanks used for storage range from 160 - 350 liters.

The system releases LN2 into the vapor mechanism at a pressure of 1,5 BAR | 22 psi up to the maximum pressure limit at 3 BAR | 43 psi.

All pressurized/nitrogen tanks require regular deliveries of liquid nitrogen to operate.
Unrestricted access is essential for the mobility of storage vessels and seamless deliveries into the facility.
The standard consumption of the CRYO XC™ Pressurized System ranges between 4 - 8 liters  per session under regular conditions.

Liquid Nitrogen Characteristics

Liquid Nitrogen offers one of the most easily storable and usable coolants available to the general public.

The CRYO XC™ uses liquid nitrogen as a coolant for its extremely cold properties that allow for a rapid cooldown & immediate thermal shock for the client.
A cryotherapy chamber must be able to efficiently & safely process liquid nitrogen and fully transform it into a gas that is released into the cabin.
Any loose liquid nitrogen that enters the client cabin can be potentially dangerous for the client. The possibility of such conditions must be prevented by the cryotherapy chamber.

The abbreviation for Liquid Nitrogen is LN2 or LIN

1 liter of LN2 = 0.8 Kg / 1.76 lbs
1kg / 2.20 lbs of LN2 = 1.2349 liters

Standard Consumption

  • The standard consumption of the CRYO XC™ is a result of an extensive series of tests conducted in rigorous work environments and conditions.          
  • Different settings and conditions may result in different outcomes of consumption.

Consumption of LN2 in a cryotherapy chamber is mostly determined by the physical settings & equipment used:

  • Intensity of session (Temperature Settings on the CRYO XC™)
  • Length of Session (Time Settings on the CRYO XC™)
  • Specification of Pressurized/Nitrogen tank (Internal Pressure of the tank)
  • Specification of Transfer Lines (Type of Transfer Hose)

 

Besides the importance of physical settings & equipment:

  • The consumption of a cryotherapy chamber is also determined by scheduling & management of daily operation (Operator).  
  • Minimizing inactivity of the unit between sessions increases efficiency.

Technical Considerations

The main points to consider when deciding to buy a cryotherapy chamber.mption.

  • Consumption
    • Most open top cryotherapy chambers or cryosaunas available today offer similar levels of consumption.
    • Manufacturers may state consumption in liters per minutes.
    • Manufacturers may state consumption in Kg/Lbs, instead of the generally accepted standardin Liters/session.
  • Quality of Session
    • Balanced Temperature throughout cabin.
    • Realistic Temperature in cabin.
  • Safety
    • Safety Features
    • Safety Record
    • Certification
  • Build Quality
    • Material used
  • Level of Service
    • Technical Support
    • After-Warranty Care

Capacity & Readiness

CRYO XC™  |  Non-Pressurized System

The CRYO XC™ Non-Pressurized System is suitable for:

  • Cryotherapy Start-Ups, Private Use
  • Wellness / Recovery centers, Spa’s, Sports clubs, Fitness centers, Training centers & Rehabilitation facilities, beauty centers, home use, private & exclusive settings

The CRYO XC™ Non-Pressurized System cryotherapy chamber runs on electric power while using liquid nitrogen to cool the cabin.
For this system, Liquid Nitrogen is stored in storage vessels called dewar vessels with a capacity of 50 liters each.
The dewars used to supply the CRYO XC™ are exclusively supplied with CRYONiQ products and are not interchangeable.

The system works by feeding LN2 into the vapor mechanism with rapid bursts of air, not requiring any containers under pressure.

All dewar vessels require regular deliveries of liquid nitrogen to operate.
Unrestricted access is essential for the mobility of storage vessels and seamless deliveries into the facility.
The standard consumption of the CRYO XC™ Non-Pressurized System ranges between 3 - 7 liters  per session under regular conditions.

Liquid Nitrogen Characteristics

Liquid Nitrogen offers one of the most easily storable and usable coolants available to the general public.

The CRYO XC™ uses liquid nitrogen as a coolant for its extremely cold properties that allow for a rapid cooldown & immediate thermal shock for the client.
A cryotherapy chamber must be able to efficiently & safely process liquid nitrogen and fully transform it into a gas that is released into the cabin.
Any loose liquid nitrogen that enters the client cabin can be potentially dangerous for the client. The possibility of such conditions must be prevented by the cryotherapy chamber.

The abbreviation for Liquid Nitrogen is LN2 or LIN

1 liter of LN2 = 0.8 Kg / 1.76 lbs
1kg / 2.20 lbs of LN2 = 1.2349 liters

Standard Consumption

  • The standard consumption of the CRYO XC™ is a result of an extensive series of tests conducted in rigorous work environments and conditions.          
  • Different settings and conditions may result in different outcomes of consumption.

Consumption of LN2 in a cryotherapy chamber is mostly determined by the physical settings & equipment used:

  • Intensity of session (Temperature Settings on the CRYO XC™)
  • Length of Session (Time Settings on the CRYO XC™)
  • Specification of Pressurized/Nitrogen tank (Internal Pressure of the tank)
  • Specification of Transfer Lines (Type of Transfer Hose)

 

Besides the importance of physical settings & equipment:

  • The consumption of a cryotherapy chamber is also determined by scheduling & management of daily operation (Operator).  
  • Minimizing inactivity of the unit between sessions increases efficiency.

Technical Considerations

The main points to consider when deciding to buy a cryotherapy chamber.mption.

  • Consumption
    • Most open top cryotherapy chambers or cryosaunas available today offer similar levels of consumption.
    • Manufacturers may state consumption in liters per minutes.
    • Manufacturers may state consumption in Kg/Lbs, instead of the generally accepted standardin Liters/session.
  • Quality of Session
    • Balanced Temperature throughout cabin.
    • Realistic Temperature in cabin.
  • Safety
    • Safety Features
    • Safety Record
    • Certification
  • Build Quality
    • Material used
  • Level of Service
    • Technical Support
    • After-Warranty Care

Select Your System

CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in whiteCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tankCryotherapy machine with pressurized tank vesselCryotherapy machine with non-pressurized storage tank

4 to 8 liters

Consumption

-150°C | -240°F

Max Temperature

Up to 15

Clients p/h

5 to 8 liters

Consumption

-150°C | -240°F

Max Temperature

Up to 15

Clients p/h

4 to 7 liters

Consumption

-150°C | -240°F

Max Temperature

Up to 15

Clients p/h

Customization & Specs

CRYO XC™  Plus |  CRYO XC™

Orientation

Right-Oriented

Right-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the right hand side.

The operator touchscreen installed on the right is default orientation for the CRYO XC™ Plus and CRYO XC™.

Left-Oriented

Left-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the left hand side.

Custom

The Custom option allows the installation of the operator touchscreen on a solid surface separate from the CRYO XC™ Plus or CRYO XC™ such as walls, panels or the CRYONiQ stand. This option is designed to provide additional flexibility to the operator and clients. Maximum distance from the unit is 15 ft / 5 m.

Custom orientation requires physical adjustments on the CRYO XC™/CRYO XC™ Plus and carries an additional fee. Get in touch with a CRYONiQ representative to find out more about the CRYONiQ Panel.

CRYO XC™  Plus |  CRYO XC™

Exterior Branding

The outer shell of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with branding and customized designs.
Exterior branding requires submission of the selected graphic material. Exterior branding carries an additional fee.

CRYO XC™  Plus |  CRYO XC™

Interior Branding

The interior of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with customizable embroidery sewn into the fabric.
Interior branding requires submission of the selected graphic material. CRYONiQ embroidery is included by default. Customization of the interior carries an additional fee.

CRYO XC™  Plus |  CRYO XC™

Physical Specs

Height:

7 ft 3 in
222 cm

Width:

3 ft
90 cm

Depth (Closed):

5 ft
150 cm

Depth (Closed):

5 ft
150 cm

Span:

5 ft
150 cm

Go to Physical Specs to learn more about the size of the cryotherapy chamber and how it fits into a room.

CRYO XC™  Plus |  CRYO XC™

Orientation

Right-Oriented

Right-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the right hand side.

The operator touchscreen installed on the right is default orientation for the CRYO XC™ Plus and CRYO XC™.

Left-Oriented

Left-Oriented units have the operator controls including the touchscreen, power button and the emergency stop button installed on the left hand side.

Custom

The Custom option allows the installation of the operator touchscreen on a solid surface separate from the CRYO XC™ Plus or CRYO XC™ such as walls, panels or the CRYONiQ stand. This option is designed to provide additional flexibility to the operator and clients. Maximum distance from the unit is 15 ft / 5 m.

Custom orientation requires physical adjustments on the CRYO XC™/CRYO XC™ Plus and carries an additional fee. Get in touch with a CRYONiQ representative to find out more about the CRYONiQ Panel.

CRYO XC™  Plus |  CRYO XC™

Exterior Branding

The outer shell of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with branding and customized designs.
Exterior branding requires submission of the selected graphic material. Exterior branding carries an additional fee.

CRYO XC™  Plus |  CRYO XC™

Interior Branding

The interior of the CRYO XC™ Plus and CRYO XC™ can be personalized to your needs with customizable embroidery sewn into the fabric.
Interior branding requires submission of the selected graphic material. CRYONiQ embroidery is included by default. Customization of the interior carries an additional fee.

CRYO XC™  Plus |  CRYO XC™

Physical Specs

Height:

7 ft 3 in
222 cm

Width:

3 ft
90 cm

Depth (Closed):

5 ft
150 cm

Depth (Closed):

5 ft
150 cm

Span:

5 ft
150 cm

Go to Physical Specs to learn more about the size of the cryotherapy chamber and how it fits into a room.

Select Exterior Color

CRYO XC™ Cryocabin in anthracite grayCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientationCRYONiQ cryotherapy chamber right orientationCRYONiQ cryotherapy chamber left orientationCRYONiQ cryotherapy chamber custom orientation

Flexible

Orientation

Customizable

Branding*

Smooth

Install

Select Interior Color

Black interior of Cryotherapy chamberGray interior of Cryotherapy chamberLight Blue interior of Cryotherapy chamberBlue interior of Cryotherapy chamberGray interior of Cryotherapy chamber
Black interior of Cryotherapy chamber CRYO XC™ PlusGray interior of Cryotherapy chamber CRYO XC™ PlusLight blue interior of Cryotherapy chamber CRYO XC™ PlusDark blue interior of Cryotherapy chamber CRYO XC™ PlusRed interior of Cryotherapy chamber CRYO XC™ Plus

Aircraft Design

Door Frames

Customizable

Embroidery*

Cold Resistant

Fabric

Summary of additional options

REQUEST PRICE

Select options

Scroll through our range of products and services and learn about our options.

LN2 storage options include nitrogen tanks used for storing the required coolant for all CRYONiQ Whole Body Cryotherapy units and Localized Cryotherapy devices.
These include pressurized tanks for the Pressurized system ranging from 120 liters, 180 liters, 240 liters and bulk storage tanks over 500 liters.
For the Non-Pressurized System, we offer non-pressurized dewar vessels that carry up to 50 liters of LN2. Learn More
Pressurized tanks for storage of liquid nitrogen
LN2 Storage OptionsSelectDetails
We offer a selection of stock and customized transfer hoses, pressure relief vents and other items necessary for the operation of nitrogen-cooled cryotherapy equipment.
Get in touch with our team to find out more.
Armored jacketed cryogenic transfer hose
Cryogenic AccessoriesSelectDetails
Wearing personal protective equipment (PPE) is one of the mandatory requirements while handling LN2, but also for the user inside the the whole body cryo chamber.
Check out our range of items and find PPE for both equipment operators and daily cryotherapy users.
Safety collar for cryotherapy treatments
Operation Guidelines ensure that customers have a safe experience running and using our equipment starting from day one.
Guidelines for daily operation can also improve efficiency of operation.
Operation guidelines for cryotherapy center
Operation GuidelinesSelectDetails
Localized Cryotherapy, also called Spot Cryotherapy or a Cryofacial is a useful treatment for any location doing cryo or recovery.
Localized Cryotherapy allows the operator to apply rapid cold treatments in a more coordinated way and target troublespots.
Select to find out more about the CRYO LC.
CRYO LC cryotherapy machine in center
Local/Spot CryotherapySelectDetails
CRYONiQ offers installation for of all new WBC equipment with a professional approach.
Select this option to find out about the process or go to CRYO XC™ installation. Learn More
Cryotherapy equipment install by CRYONiQ technician
WBC InstallSelectDetails
Get Insurance coverage for your cryotherapy business.
Assistance with cryotherapy insurance may not be available in all territories. Learn More
Cryotherapy insurance for business and home
Cryotherapy InsuranceSelectDetails
Electric Cryochambers offer a different experience to nitrogen cooled systems both in terms of service and customer experience.
EC's operate on electricity and do not require LN2 to run.
In some cases this can be an advantage especially for facilities that can't be serviced by an LN2 supplier.
Select this option to get offers and information about electric cryotherapy chambers. Learn More
Electric cryochamber and cryotherapy machine
Electric CryochambersSelectDetails
Hydromassage beds offer a relaxing experience to all users. Hydromassages are popular in office relaxation areas, but can be popular additions to businesses or for private use.
Get in touch with our team to find out more about hydromassage beds.
Wellsystem Hydromassage Bed
Hydromassage BedsSelectDetails
Find out if you can get nitrogen service in your area or get a quote on LN2.
This service is intended for those looking to purchas CRYONiQ products for their business, training facilities or home gym. Learn More
Liquid Nitrogen suppliers
Gas RelationsSelectDetails
Get ideas for your cryotherapy facilities from our selection of Furnishing options for Individuals & Businesses.
Options include decoration, furniture, useful tools for operators and customers.
Furnishing for waiting room in cryotherapy center
FurnishingSelectDetails
Operator training is an integral part of every equipment install. We offer annual training courses and refresher training on CRYONiQ products.
Select to receive more information about CRYONiQ training or follow the link to Operator Training. Learn More
Cryotherapy equipment training by CRYONiQ technician
Operator TrainingSelectDetails
Find out more about our technical support.
Our additional service packages expand coverage for equipment both in and out of warranty and for equipment eligible for an extension of an existing warranty. Learn More
Cryotherapy services and packages from CRYONiQ
Service & WarrantySelectDetails
Percussive therapy or vibration therapy apples a rapid burst of pressure on muscle tissue.
Massage guns are used to treat muscle tension, soreness and cramps, and have proven to be a good choice for physiotherapists and sport enthusiasts that combines well with cryotherapy .
Get in touch with our team to receive a list of options.
Theragun massage gun
Percussive TherapySelectDetails
Compression therapy has become an established recovery modality for both pro athletes and everyday athletes.
Get in touch with our team to receive a list of options.
Normatec recovery gear and accessories
Compression TherapySelectDetails
As part of our service, we offer certified used cryotherapy machines. Select this option for additional information. Learn More
Three cryosaunas next to each other
Pre-Owned EquipmentSelectDetails
Get assistance on setting up a new cryotherapy & recovery center or home gym.
Project assistance includes a list of services such as bulk gas sourcing, cryotherapy insurance, assistance with safety & conformity, financing options, marketing, install & operator training, delivery & import. Learn More
CRYONiQ cryotherapy center
Project AssistanceSelectDetails
Extend the Warranty on your CRYONiQ product. Learn More
Extended Warranty for cryotherapy products
Extended WarrantySelectDetails

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Systems

Pressurized | Non-Pressurized

Pressurized system

Non-Pressurized system

PRESSURIZED

Non-PRESSURIZED

Description

The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
 

The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

AVAILABILITY

CRYO XC™ Plus
CRYO XC™

CRYO XC™ Plus
CRYO XC™

MEDIUM

The Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

The Non-Pressurized System is cooled by Liquid Nitrogen (non-medical grade)

Storage

Low capacity tanks

Standard capacity tanks

High capacity tanks

Optimum Pressure

*Pressurized tanks are not included.

70 L, 160 L

180 L, 240 L, 320 L, 350 L

500 L, 750 L, 1000 L

1,5 to 2,5 BAR  |  22 to 37 psi

Standard Tank (Dewar)

*Two dewar vessels are included with the non-pressurized system.

50 L (Non-Pressurized)

CONSUMPTION

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

5 to 8 Liters*

Max 4000W; Session 1000W;

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

Consumption (LN2) -

Consumption (Electricity) -

 

Precool -

4 to 7 Liters*

Max 4000W; Session 1000W

Idle 140W; Drying 3400W

2 - 4 Liters (LN2)

ROOM REQUIREMENTS

Minimum
Recommended

20 m2   |   200 sqft
25 m2   |   270 sqft

The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

Minimum
Recommended

15 m2   |   160 sqft
25 m2   |   270 sqft

The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

The recommended ceiling height is 240 cm / 8 ft

For more info go to Room Requirements

SUITABLE FOR

High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

APPROVAL

The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

1

Customer selects Products, Options & Services¹

  • All new customized equipment is made-to-order.
  • Our Existing Inventory offers new stock equipment.
2

CRYONiQ confirms acceptance and verifies selection

3

CRYONiQ prepares a Price Quote

  • According to the customers selection of items.
  • Payment terms may vary for select territories and products.
4

Customer selects form of financing ²

  • The Customer must select their preferred payment method
  • The Customer provides billing details
  • Financing Options are available.
5

CRYONiQ prepares Equipment Order Agreement (EOA)

  • The EOA includes the Equipment Configuration and Terms of Purchase.

6

CRYONiQ issues an invoice for selected items.

  • A 50% non-refundable deposit is required to validate an order for made-to-order equipment.
  • A 100% deposit is required to validate an order for Pre-Owned Equipment.
7

Production & Lead Time

  • A signed Equipment Order Agreement and Deposit are required to begin production
  • Production takes 4 to 8 weeks upon receiving a valid order
  • Expedited delivery may be available in some cases for a fee.
  • Due to supply chain issues, it may be difficult to guarantee an exact delivery date, unless secured sufficiently in advance.
  • We do not offer any compensation for logistics delays.
8

Cancellation of Order⁵

  • Can be made within 3 days of submitted order at no cost except accrued transfer charges.
9

Preparation for Delivery, Install and training

10

Final payment is due before shipping

  • Final Payment is due before the ordered product(s) is shipped. Exceptions may apply.
11

Transfer of Ownership

  • CRYONiQ shall retain title to the delivered goods until fulfilment of all claims under the supply contract.

¹ Items selected from the Inventory and Pre-Owned inventory may carry different Terms of Purchase than products made-to-order..
² Payment options & terms may vary for leases, rentals and other financing products.
³ Payments must be made in the following currencies USD - United States. EUR - European Union ; GBP - United Kingdom; EUR - Rest of World; Exceptions may apply
⁴ In case of cancellation after 3 work days, owing to the made-to-order nature of the product, CRYONIQ reserves the right to retain the received deposit in full. Any return and the extent of such return is made at the sole discretion of CRYONiQ.
⁵ The listed order and payment terms apply to the CRYO XC™ Plus and CRYO XC™. The order and payment terms for other products can be requested individually.

CRYO XC™ Plus & CRYO XC™

Model features

Cryo XCTM PlusCryo XCTM
MODELS Cryo XCTM Cryo XCTM Plus
Description
The CRYO XC™ is CRYONiQ's best-seller. Designed to offer a balanced cryotherapy session and maximum exposure to extreme temperatures.
The CRYO XC™ Plus is CRYONiQ's flagship cryotherapy chamber which offers an enhanced cryotherapy experience for clients and operators with additional safety and design features.
Features
21,5" Touchscreen - Control Panel
15" Multimedia/Info Screen
Thermal Contrast Cryotherapy 
Adaptable Orientation
Lift
Deflectors
Active Drying System
Session Tracker
Remote Diagnostics
Safety Relief Vent
Exhaust Fan
Oxygen Monitoring
Door Sensor
Humidity Tracking
Pressure Tracking
Tremor Emergency Stop
Heart Rate Monitor

Systems

Pressurized System
Available
Compare
Available
Compare
Non-Pressurized System
Available
Compare
Available
Compare

SESSION TEMPERATURE (Exclusions Apply)

Temperature Range (Recommended)
170°F to -200°F
-110°C to -140°C
-170°F to -200°F
-110°C to -140°C
Temperature Range (Expanded)
-170°F to -240°F
-110°C to -160°C
-170°F to -240°F
-110°C to -160°C

STORAGE TANKS

Pressurized System
Tanks not included
Tanks not included
Non-Pressurized System
2x 50 liter vessel included
2x 50 liter vessel included

LN2 CONSUMPTION 

Pressurized System
5 - 8 liters (LN2)
5 - 8 liters (LN2)
Non-Pressurized System
4 - 7 liters (LN2)
4 - 7 liters (LN2)
Precool
2 - 4 Liters (LN2)
2 - 4 Liters (LN2)

ELECTRICAL SPECIFICATION

Outlet Voltage
230V
230V
Frequency
50 Hz
50 Hz
Amperes (Amps)
min. 16 A
min. 16 A
Power Usage
Max: 4000W
Idle: 140W
Session: 1000W
Drying: 3400W
Max: 4000W
Idle: 140W
Session: 1000W
Drying: 3400W

Certification

CE Mark
FDA 513g Non-Medical Device

LEAD TIME

New & Made-To-Order
4 to 6 weeks from valid order
4 to 6 weeks from valid order
Existing Inventory | Stock Items
1 to 2 weeks from valid order
1 to 2 weeks from valid order
Pre-Owned Inventory
1 to 2 weeks from valid order
1 to 2 weeks from valid order
Express Delivery
Faster Delivery of Made-To-Order Equipment
Faster Delivery of Made-To-Order Equipment

Warranty

2 Year Limited Service Warranty
2 Year Limited Parts Warranty
3 Year Limited Service Warranty
Available
Available
3 Year Limited Parts Warranty
Available
Extended Warranty
Available
Available

SERVICES (Exclusions Apply)

Door to door delivery
On-Site Install
On-Site Operator Training
24/7 Tech Support
First LN2 Fill for Operator Training*
Risk Assessment (Remote)

PROJECT ASSISTANCE (Exclusions Apply)

LN2 Supplier Sourcing
Available
Available
Financing Options | Lease Options
Available
Available
Insurance Options
Available
Available
Safety Regulations | Risk Assessment
Available
Available
Operation Guidelines
Available
Available



Your Customized

Summary

Cryo XCTM

CRYO XC™ Cryocabin in anthracite grayCRYO XC™ Plus Cryocabin in blackCRYO XC™ Cryo machine in blueCRYO XC™ Cryotherapy unit in grayCRYO XC™ Cryotherapy unit in white

Specs & General Terms:

Standard Lead Time: 4 to 8 weeks
CRYO XC™ Plus & CRYO XC™ Features
Order Process & Payment Terms
Delivery & Packaging

Selected Options:

Additional Options:

Additional Information

Please provide additional information on your enquiry. By filling out this information, you're helping us improve our services.

Field | Industry

Objective

Interested In

Product Support

Request a Custom Quote

Fill out this form to receive a Custom Quote.

By providing a telephone number and submitting this form you are consenting to be contacted by SMS text message. Message & data rates may apply. You can reply STOP to opt-out of further messaging.

Thank you for submitting
your request.

We will respond to your inquiry shortly.

 

For quick customer service choose one of the following options:

Chat Now or call (302) 319 9788

CRYO XC™ Plus

WBC Chamber/Cryosauna

CRYO XC™

WBC Chamber/Cryosauna

CRYO LC

Local Cryotherapy Device

CRYONIQ LLC | 919 North Market St., Wilmington, DE, 198 01

PACKAGING & DELIVERY

AIR/SEA FREIGHT PACKAGING

CRYO XC™ / CRYO XC™ Plus Pressurized System

Cabin Crate

L: 80" x W: 41" x H: 47"
L: 203 cm x W: 103 cm x H: 118 cm
Weight: 612 lbs / 278.4 Kg

Tower Crate

L: 62 x W: 32 x H: 60"
L: 158 cm x W: 82 cm x H: 151 cm
Weight: 544 lbs / 246.5 Kg

CRYO XC™ / CRYO XC™ Plus Non-Pressurized System

Cabin Crate

L: 80" x W: 41" x H: 47"
L: 203 cm x W: 103 cm x H: 118 cm
Weight: 612 lbs / 278.4 Kg

Tower Crate

L: 62 x W: 32 x H: 60"
L: 158 cm x W: 82 cm x H: 151 cm
Weight: 544 lbs / 246.5 Kg

Storage Vessel Crate (2 vessels)

L: 40" x W: 40" x H: 23"
L: 102 cm x W: 101 cm x H: 58 cm
Weight: 154 lbs / 70 Kg

*All crates are non-stackable. All crates may however carry a load that does not exceed 66 lbs / 30 Kg.
*Road Freight does not require Air/Sea Freight packaging

ROAD FREIGHT PACKAGING (EU & UK)

CRYO XC™ / CRYO XC™ Plus Pressurized System

Cabin Crate

L: 80" x W: 41" x H: 47"
L: 203 cm x W: 103 cm x H: 118 cm
Weight: 612 lbs / 278.4 Kg

Tower Crate

L: 62 x W: 32 x H: 60"
L: 158 cm x W: 82 cm x H: 151 cm
Weight: 544 lbs / 246.5 Kg

Storage Vessel Crate (2 vessels)

L: 40" x W: 40" x H: 23"
L: 102 cm x W: 101 cm x H: 58 cm
Weight: 154 lbs / 70 Kg

CRYO XC™ / CRYO XC™ Plus Non-Pressurized System

Cabin Crate

L: 80" x W: 41" x H: 47"
L: 203 cm x W: 103 cm x H: 118 cm
Weight: 612 lbs / 278.4 Kg

Tower Crate

L: 62 x W: 32 x H: 60"
L: 158 cm x W: 82 cm x H: 151 cm
Weight: 544 lbs / 246.5 Kg

Storage Vessel Crate (2 vessels)

L: 40" x W: 40" x H: 23"
L: 102 cm x W: 101 cm x H: 58 cm
Weight: 154 lbs / 70 Kg

SHIPPING OPTIONS

Air Freight - Shipping time including the import and customs process is usually between 7 - 15 days
Sea Freight - Shipping time including the import and customs process is usually between 3 - 6 weeks
Road Freight - 1 to 4 days

For express delivery please get in touch with a CRYONiQ representative
If you wish to arrange delivery with your own forwarder, please inform a CRYONiQ representative.

GET A QUICK QUOTE

If you would like to receive a Quick Quote:

or Call us now+1 (302) 303 0870

Select Your Model

Cryo XCTM

Select Your System

Cryo XCTM

Select Exterior Color

Cryo XCTM

Orientation

Select Interior Color

Cryo XCTM

Options

Cryo XCTM

Options include a list of products and services that are useful when setting up and running a cryotherapy or recovery spot.

By selecting an option, you are requesting additional information about the selected item.

Choose the options that you are interested in learning more about or Skip Step.

Summary of additional options

Summary

Your Details

Additional Information

Please provide additional information on your enquiry. By filling out this information, you're helping us improve our services.

Field | Industry

Objective

Interested In

Product Support

Fill out this form to receive a Custom Quote.

By providing a telephone number and submitting this form you are consenting to be contacted by SMS text message. Message & data rates may apply. You can reply STOP to opt-out of further messaging.

Thank you for submitting
your request.

We will respond to your inquiry shortly.

 

For quick customer service choose one of the following options:

Chat Now or call (302) 319 9788

CRYONIQ LLC | 919 North Market St., Wilmington, DE, 198 01