• Home
  • Products
  • Product Configurator
  • CRYO CHAMBER GUIDE
  • SUPPORT
  • Contact
  • Systems

    Pressurized | Non-Pressurized

    Pressurized system

    Non-Pressurized system

    PRESSURIZED

    Non-PRESSURIZED

    AVAILABILITY

    CRYO XC™ Plus
    CRYO XC™

    CRYO XC™ Plus
    CRYO XC™

    Description

    The CRYO XC™ Pressurized system uses pressurized tanks and vessels for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is supplied into the system under pressure that is maintained inside the storage vessel.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.
     

    The CRYO XC™ Non-Pressurized system uses non-pressurized vessels or dewars for the storage and supply of liquid nitrogen.

    During operation, liquid nitrogen is transferred into the system with the help of pressure created by the cryotherapy unit.

    Once inside the system, the coolant is processed into gasiform air that enters the controlled environment in the client cabin.

    Storage

    Low capacity tanks

    Standard capacity tanks

    High capacity tanks

    Optimum Pressure

    *Pressurized tanks are not included.

    70 L, 160 L

    180 L, 240 L, 320 L, 350 L

    500 L, 750 L, 1000 L

    1,5 to 2,5 BAR  |  22 to 37 psi

    Standard Tank (Dewar)

    *Two dewar vessels are included with the non-pressurized system.

    50 L (Non-Pressurized)

    CONSUMPTION

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    5 to 8 Liters*

    Max 4000W; Session 1000W;

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    Consumption (LN2) -

    Consumption (Electricity) -

     

    Precool -

    4 to 7 Liters*

    Max 4000W; Session 1000W

    Idle 140W; Drying 3400W

    2 - 4 Liters (LN2)

    ROOM REQUIREMENTS

    Minimum
    Recommended

    20 m2   |   200 sqft
    25 m2   |   270 sqft

    The pressurized system requires barrier free access to the supply zone. The lightest pressurized vessels/cylinders weigh  approximately 150 Kg/ 330 Lbs when empty.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    Minimum
    Recommended

    15 m2   |   160 sqft
    25 m2   |   270 sqft

    The non-pressurized system allows for easier access from the supply zone to the cryotherapy unit. The tare weight of the dewar vessel is 17 kg / 25 Lbs and 65 Kg / 130 Lbs when full. These vessels can be carried by hand for refills.

    The recommended ceiling height is 240 cm / 8 ft

    For more info go to Room Requirements

    SUITABLE FOR

    High capacity & high footfall locations. Wellness/Recovery centers, sports organizations, fitness centers, training facilities, rehabilitation facilities, medical facilities/clinics

    Cryotherapy startups, wellness/recovery centers, spas, sports organizations, fitness centers, training facilities, beauty centers, home & private use, exclusive social clubs

    APPROVAL

    The Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.

    The Non-Pressurized System requires a risk assessment for use in the facilities from the liquid nitrogen supplier and may require approval from the city.